  1. IRR 2017

    • Protects staff & members of the public who are NOT patients
    • = Ionising Radiation regulations
    • New regulations
      • Graded approach based on perceived risk associated with IR
      • If there is a medium risk then you need to register with HSE if you are the employer in the practice
        • Online system
        • Old regulations didn't make it that deep
        • HSE = health, safety & environment
      • HSE decided that lead shielding of controlled area unacceptably expensive with little practical benefit.
    • Job Positions
      • Radiation Protection Advisor
        • Can be out of practice
        • Radiation expert who gives advice & helps practices comply with IRR
          • Risk assessment
          • Local rules
          • Staff & Public dose
          • Investigations
          • Presence at HSE inspections
          • Room design
      • Radiation Protection Supervisor
        • In practice
        • Ensures IRR followed in the practice
      • Health & Safety Executive
        • Top dog
    • Risk Assessment
    • Local Rules
      • Describes the Controlled Area
      • Who can enter the Controlled Area
      • Defines the Systems of Work
        • = what can be done in the Controlled Area
      • RPA & RPS contacts
      • All employees must read & sign
    • Monitoring of areas & people
      • Restriction of exposure
        • AS LOW AS REASONABLY PRACTICABLE
        • Opeartor to stand outside Controlled Area (when pressing button)
          • 2m switch cable
        • Local investigation level
          • May be triggered by something small
            • e.g. doing 2x normal radiograph amount due to staff shortage
        • Comforter/Carer for patient
          • Discouraged
          • If present during x-ray
            • Wear lead apron
            • Record of identify & exposures received
            • Seek RPA advice
      • Dental Controlled Area
        • = 1.5m from x-ray tube & patient in all directions (other than the primary beam)
        • For CBCT
          • Controlled area = whole room
          • Need extra RPA advice
            • May need >0.5mm of lead in walls
        • If >100 I/O or >50 DPTs per week
          • Need extra RPA advice
            • May need >0.5mm lead in walls
            • Staff monitoring
      • Dose limits
      • Notify HSE
        • Over-exposure ocurred
          • If x20 normal dose -> seek RPA advice
        • Dose limits exceeded
          • Effective dose > 6mSv
          • Equivalent dose >
            • 15mSv for eye lens
            • 150mSv for skin or extremities
          • Employer must complete dose assessment & report
        • loss, theft or release of a certain quantity of radioactive material has occurred
    • Employee responsibilities
      • Be suitably trained
      • Restrict exposure to self & others
      • Use & look after protective equipment
      • Notify of over-exposure/near misses/incidents
      • Comply with local rules & systems of work
    • Every fixed installation requires a critical exam
      • Checks safety features
      • Done by installer
  2. IRMER 2018

    • = Ionising radiation (medical exposure) regulations
    • Protects patients
    • New regulations
      • Specifically requires justification of exposures to carers or comforters
    • Job positions
      • CQC = top dog
        • Department of health responsible
      • Medical Physics Expert
        • Like RPA
        • Gives employers advice on compliance with IRMER
    • Training records
    • Employer procedures
    • Equipment Quality Assurance
      • Diagnostic reference levels
        • Reveiwed every 3yrs or if equipment/procedures change
        • Should get accurate radiographs </= these levels
        • Established for each standard diagnostic exam for a standard patient cohort
          • Based on
            • National DRLs
              • IO lower molar
                • Adult = 1.7 mGy
                • Child = 0.7 mGy
              • DPT
                • Adult = 93 mGy
                • Child = 67 mGy
              • CBCT
                • 250 mGy
            • Doses measured in QA programme
          • Expressed in dose quantities depending on type of equipment & exam e.g. mAs, DAP
        • Investigation required if these are regularly exceeded
          • Improved via optimisation
      • Practice employees should regularly check
      • Physics QA
        • Do every 3yrs minimum
        • Assesses dose to pt.
      • Testing
        • Acceptance test
          • done before use of equipment
        • Performance testing
          • Routinely & after maintenance
    • Roles of duty holders
      • Employer
        • Ensure compliance
        • Written procedures
        • Referrer guidelines
          • Selection criteria for Dental radiography (FGDP)
        • QA & clinical audit
        • Appoint MPE
          • May be same person as RPA
        • DRLs
        • Equipment list
        • Training
      • Referrer
        • Follow employer referral guidelines
        • Provide info about pt.
          • Sufficient clinical info for Practitioner to justify radiograph
          • History & clinical exam required
          • Correct identification of pt.
      • Practitioner
        • Justify exposures
          • Previous radiographs available?
          • Benefits outweigh radiation risk?
          • Will exposure give new info/change pt. management or prognosis?
          • Clinical evaluation of radiograph must take place & be recorded
            • If not then exposure not justified
        • Follow employer procedures
      • Operator
        • Perform exposures
          • Presses the button
          • Must have sufficient training
          • Correct identification
        • Optimise dose
          • Optimisation = obtaining diagnostic info at ALARP dose
          • How
            • Correct selection of exposure factors
              • If not followed -> record exposure factors
              • Shortest exposure time poss.
            • Increase sensitivity of image receptor
              • E speed or faster film
            • Reduce area exposed
              • Collimator
              • Ensure sensitive tissues are in low dose area
            • Optimal voltage = 60-70kV
        • Follow employer procedures
        • Processes radiograph
      • Dentist = R + P + O
  3. Grading according to FGDP guidelines

    • Grade 1
      • Excellent
      • No errors of exposure/positioning/processing
      • Should be >70%
    • Grade 2
      • Diagnostically acceptable
      • May have exposure/positioning/processing error
        • Does not detract from diagnostic utility
      • <20%
    • Grade 3
      • Do an audit of IRMER
      • Must record
        • Date
        • Nature of error
        • Known/suspected cause of error
        • Number of repeats taken
        • Total number taken during same period
      • Diagnostically unacceptable
        • Needs repeating
      • <10%
  4. X-ray viewing

    • May take up to 30% demineralisation to occur before caries visible radiographically
    • Don’t mistake cervical burnout space between enamel and bone overlying tooth will appear more radiolucent than enamel or bone-tooth combination
    • Must note any changes of lamina dura in radiographs
  5. Pregnancy

    • Can have dental radiographs (IO & DPT)
      • No need for lead apron
    • Limit before the 9 weeks
    • Foetus dose limit = 1mSv
  6. Radiation incident reports

    • Equipment failure
    • Geographical miss or wrong anatomy
    • Near miss
    • Overexposure
    • pt was not intended to receive exposure
  7. Radiographic Faults

Information

Description
First Year Dentistry Mind Map on Rules & Regulations Radiology, created by sanna pathy on 08/03/2020.
Created by
sanna pathy
Views
3
Tags
oral diseases
History
  • Created by Zainab Patel · Feb 1, 2020
  • Copied by sanna pathy · Mar 8, 2020
Rating

More on Radiation Safety and Regulations

Feedback

What is it about?

What should we add next?